Home > Cannot Open > Cannot Open Device 5 I O Error Data Protector

Cannot Open Device 5 I O Error Data Protector

Categories Data Protector 5.5, Data Protector 5.5, Data Protector 6.0, Data Protector 6.11 DP Commands 11 May Omniback for the System Administrator   Glossary   Term Definition Cell Contains cell manager, A little further info: backups across the network work fine. Following is my setup:OS: Solaris 10 3/05 SPARCTape Library: Storedge L25 with 2xHP Ultrium-3 drivesDriver for exchanger: sgenDriver for tape drives: stPackages installed for host:CORE - PHSS_38741/PHSS_38742/DPSOL_00356/DPLNX_00063MA - PHSS_38410/PHSS_38411/DPSOL_00347/DPLNX_00059DA - PHSS_38408/PHSS_38409/DPSOL_00346/DPLNX_00058st.conf:"HP This can happen in the following cases: You misconfigured the device (for example, using the omniupload command, or if you configured an incorrect device file). navigate here

below are the error codes.=================================[Major] From: [email protected] "HP_LTO3_1.4" Time: 4/6/2007 3:42:18 PM[90:51] /dev/rmt/12mn Cannot write to device ([5] I/O error)[Critical] From: [email protected] "db2s24" Time: 4/6/2007 3:42:18 PM Received ABORT request from recycle, or set relevent retention periods 2. If the driver package does not include the DisableAutoRun.reg file, manually edit the system registry using RegEdit. You can change the block size of the device.

Cell Manager Data protector control software is installed here and it is where the cell is administered. After you have run this command for each device you wanted to change, move the media associated with the reconfigured devices from the current media pool to the media pool corresponding IMPORTANT: Adding or removing tape drivers from the system may cause an older driver .inf file to be re-read, which in turn can re-enable RSM polling.

After completing the above steps reboot the affected system. Categories Data Protector 5.5, Data Protector 5.5, Data Protector 6.0, Data Protector 6.11, Data Protector 6.21 Data Protector – 64bit.a errors onupdate 9 May If you get error below, run OS By product … Solution to the error: Windows cannot access the specified device, path, or file. Set goals, and work to achieve them 0 Kudos Joseph T.

I have read that the write/read needs additional storage to temporarily hold the database. Temporarily set the omnirc option OB2CRCCHECK on the media agent host to 0. A path in a multipath device is misconfigured. In my opinion and in my environment (about 15 Deviceserver Sol 10) the DeviceFile should be /dev/rmt/*cbn.m stands in HPUX for mediacompress.

or a Source/Destination? Data Protector is not aware of any command that came and merged into the command stream, since this happens at the lower level in the software. In case the medium header sanity check detects any header consistency errors on the medium, an error message is displayed and all objects on the medium are marked as failed. We usually talk about MMDB - the Media Management Database and CDB, the Catalog Database.

The tape was rewound by another application that uses the rewind device file on HP-UX. 3. NewMediaClass is the new media type of the devices, for example, T9940 for 9940 devices, T3592 for 3590 devices, and SuperDLT for SuperDLT devices. CLIReference.pdf (a repetition of the man page, but perhaps more readable)  -in your Windows (GUI) server C:Program FilesOmniBackDocsMAN  -on UX /opt/omni/docs/C/…  3. Ensure that the Firmware level & Device drivers for the HBAs used are up to date. 4.

If the medium header is corrupt, all objects on the affected medium are marked as failed and the medium is marked as poor. check over here cd /somedir omnitrig –stop       - Stop scheduled baqkups omnidbutil -writedb  -mmdb L:DumpDirmmdb  -cdb  L:DumpDircdb You can add the –no_detail switch but that will not dump out the “fnames” omnidbinit – to initialize When creating the backup job we can enable or disable this option by checking the check box. 2. Showing results for  Search instead for  Do you mean  Menu Categories Solutions IT Transformation Internet of Things Topics Big Data Cloud Security Infrastructure Strategy and Technology Products Cloud Integrated Systems Networking

By using this site, you accept the Terms of Use and Rules of Participation. End of content United StatesHewlett Packard Enterprise International CorporateCorporateAccessibilityCareersContact UsCorporate ResponsibilityEventsHewlett Packard LabsInvestor RelationsLeadershipNewsroomSitemapPartnersPartnersFind a PartnerPartner Switch on the robotics. A6. his comment is here Device open problem Problem Action When trying to use a DDS device, the following error displays: Cannot open device (not owner) Check whether you are using a medium that is incompatible

Data Protector may fail to manage devices if other device drivers are loaded on the same system. b. When device operations such as media formatting or scanning are started, the following error displays: Cannot access exchanger control device On the system where the devices are located, list all physical

Abort code -2.[Major] From: [email protected] "HP_LTO3_1.4" Time: 4/6/2007 3:42:20 PM[90:159] Apparently SCSI Unit Attention.[Major] From: [email protected] "HP_LTO3_1.4" Time: 4/6/2007 3:42:20 PM[90:162] Skipping write of filemark. (Apparently SCSI Unit Attention).[Major] From: [email protected]

SHAREDLIB = 1 SHAREDDRIVE =1 are the options for the robotic controller and the drive respectively. Also, I have notice "st_san_safe" kernel is appear in other servers, but not the server having the problem.Thanks. The medium quality statistics feature is disabled by default. Any help would be much appreciated.Thanks. 0 Kudos Reply All Forum Topics Previous Topic Next Topic 1 REPLY Erik Schubert Occasional Advisor Options Mark as New Bookmark Subscribe Subscribe to RSS

You replaced the physical device without updating the corresponding logical device (reloading the new serial number). What is NSR's?Our library connected via SAN and the connection is ok. Update Insight agent to latest version and double check that the “Disable Fibre Agent Tape Support” check box is flagged. http://d3euro.com/cannot-open/cannot-open-msn-mail.php restart Data protector services c.

If the customer is having the problem at the same time as a restore which uses the same physical device, I could see this being relevant.Errno 6. Disable Pooling in UNIX servers: 1. Either the option Automatically discover changed SCSI address is not enabled or the omnirc option OB2MADETECTDRIVESWAP is set to 0.