Home > Bus Error > Catalyst Bus Error

Catalyst Bus Error

Contents

Retrieve Information from the Crashinfo File The crashinfo file is a collection of useful information related to the current crash stored in bootflash or Flash memory. SW_VLAN-4-MAX_SUB_INT Problem The switch reports this error message: %SW_VLAN-4-MAX_SUB_INT : The number of sub-interfaces allocated for interface [chars] has exceeded recommended limits of [dec] This example shows the console output that End with CNTL/Z. Find all posts by Hlingler #8 28th October 2009, 06:24 AM HMSS013 Offline Registered User Join Date: Nov 2006 Posts: 512 i don't suppose anyone knows where i

This command is a compilation of many other Cisco IOS Software commands which includes: show version show running-config show stacks After a crash occurs, you must capture this information before a There are no negative effects on the switch because it drops the packets. MSFC or MSFC2 Does Not Respond to the telnet or session x Command Determine if this error message or a similar message displays for the standby MSFC when you issue the This sub-reddit is dedicated to higher-level, more senior networking topics. /r/itcareerquestions /r/ccna and /r/ccent are all available for early-career discussions.

System Returned To Rom By Address Error At Pc

Prerequisites Requirements There are no specific requirements for this document. These are the two kinds of parity errors: Soft parity errorsThese errors occur when a Single Event Latch up (SEL) happens within the chip. The MSFC2 has only one DRAM slot. Workaround You can manually raise the L2 limit.

This indicates a hardware problem. Issue the switch console command. Workaround Issue the show fm fie flowmask command in order to determine the NetFlow shortcut installation enable / disable status for the feature. System Returned To Rom By S/w Reset After you correct the anomaly, the messages cease. %AAAA-3-BADREG: Illegal registry call Message Displays This section addresses a Catalyst switch with MSFC that gets this message in the console or syslog:

The MSFC2 has a MIPS R7000 CPU that runs at 300 MHz internally. System Returned To Rom By Bus Error At Pc 0x0 Address 0x0 Identifying Bus Error Crashes The system encounters a bus error when the processor tries to access a memory location that either does not exist (a software error) or does not respond If you reseat the module, it realigns the switch fabric and ensures a firm connection to the backplane. Well, that's why we keep three kernels by default.

The only concern is that there is a device that sends bad packets. System Returned To Rom By Error - A System Error A specific log message cannot be filtered without affecting other logs under, which are under the same severity level. The two devices that cause the late collision never see that the other is sending until after it puts the entire packet on the network. Complete these steps in order to troubleshoot this issue: Disable IGMP snooping with the command no ip igmp snooping.

System Returned To Rom By Bus Error At Pc 0x0 Address 0x0

Troubleshoot Based on Error Messages For Cisco Catalyst 6000/6500 Switches that run Native IOS, refer to Common Error Messages on Catalyst 6500/6000 Series Switches Running Cisco IOS Software. This message normally occurs because the route processor receives a much higher than expected rate of IGMP join packets or normal multicast packets destined to reserved Layer3/Layer2 multicast address ranges. System Returned To Rom By Address Error At Pc If this problem occurs, error messages similar to these are logged in the show context output: Router#show context ... Bus Error Linux Invalid device specified Booting from default device Initializing ATA monitor library...

Other Parity Related Errors The MSFC2 contains ECC memory protection. While you enable MLS fast aging time, initially set the value to 128 seconds. Give serious consideration to installing the most recent maintenance release of the Cisco IOS software train that you are currently running. The error message looks similar to this: Mar 9 12:12:24.427 GMT: %PM_SCP-SP-1-LCP_FW_ERR: Module 6 is experiencing the following error: Pinnacle #0 PB parity error. "last Reload Reason Address Error At Pc"

Looks like Vince will be skipping kernel-2.6.30.9-90 V Hlingler View Public Profile Visit Hlingler's homepage! The [dec] is the module number, and [chars] is the error. The show region output is part of the show tech-support output from Cisco IOS Software Release 12.0(9). If the line card has TCAM information during the SNMP poll, the data is given to the network management system (NMS) for further processing.

If your network is live, make sure that you understand the potential impact of any command. System Was Restarted By Bus Error At Pc loadprog: error - on file open boot: cannot load "cisco2-Cat6k-MSFC" Problem The switch reports this error message: loadprog: error - on file open boot: cannot load "bootflash:c6msfc2-boot-mz.121-8a.EX" Description The problem occurs Don't ask us what we would buy for a given project.

All computer and network systems are susceptible to the rare occurrence of Single Event Upsets (SEU), sometimes described as parity errors.

The information in this document was created from the devices in a specific lab environment. Router#copy bootflash:c6msfc2-boot-mz.121-8a.EX ? The cause of the issue is a device on the network that sends out bad packets. Bus Error (load) Exception If this problem occurs, error messages similar to these are logged: %VIP2 R5K-1-MSG: slot0 System reloaded by a Bus Error exception %VIP2 R5K-1-MSG: slot0 caller=0x600BC974 %VIP2 R5K-1-MSG: slot0 System exception: sig=10,

Disable Telnet Access to MSFC In CatOS software mode, you can disable Telnet access to the MSFC from all devices, which includes the switch (Supervisor Engine). In most cases, this is a one time/transient issue. Late collisions are not detected by the transmitter until after the first 64 byte slot time. Switch(config)#no mls verify ip same-address !--- This configures the switch to discontinue checks for packets that have the !--- same source and destination IP addresses. %MLS_STAT-SP-4-IP_CSUM_ERR: IP checksum errors Problem The

Prerequisites Requirements There are no specific requirements for this document. For DFC-enabled modules, the diagnostic packet is sent from the inband port of the supervisor engine Home Forums Posting Rules Linux Help & Resources Fedora Set-Up Guides Fedora Magazine Ask Issue the set command in order to find the contents of the boot variable. If no response is received after 3 pings (6 seconds), it is counted as the first failure.

The only way to detect the device is to use a sniffer to track down the source and then replace the device. %EARL_L3_ASIC-SP-3-INTR_WARN: EARL L3 ASIC: Non-fatal interrupt [chars] Problem The permalinkembedsaveparentgive gold[–]snowbirdie -5 points-4 points-3 points 2 years ago(1 child)Look, you've just wasted days troubleshooting a problem instead of spending one minute to open a TAC case. If the error message is seen on all of the line cards, the cause is an improperly seated module. This information is essential in order to determine the cause of the problem: Crashinfo files—When an MSFC or MSFC2 crashes, the device attempts to write a crashinfo file to its bootflash.

Then, either stop the transmission or modify the characteristics of the stream so that the transmission no longer infringes upon the IGMP control data space. In hybrid mode, it is expected behavior that network file systems do not support these commands: dir delete squeeze How to Disable the MSFC or Routing Module In order to disable